Carrier Furnace Secondary Heat Exchanger Problems

Heat Exchanger Problem With The Carrier 398aaw Youtube

Heat Exchanger Problem With The Carrier 398aaw Youtube

Bad Secondary Heat Exchanger Youtube

Bad Secondary Heat Exchanger Youtube

Heat Exchanger Crack Diagnosis Hvac School

Heat Exchanger Crack Diagnosis Hvac School

Carrier Heat Exchanger Failures Warranty Program

Carrier Heat Exchanger Failures Warranty Program

Carrier Bryant Payne Heat Exchanger Failure Youtube

Carrier Bryant Payne Heat Exchanger Failure Youtube

Amana Gas Furnace Reviews Pricing Guide Quality Rating 101 Gas Furnace Carrier Gas Furnace Furnace

Amana Gas Furnace Reviews Pricing Guide Quality Rating 101 Gas Furnace Carrier Gas Furnace Furnace

Amana Gas Furnace Reviews Pricing Guide Quality Rating 101 Gas Furnace Carrier Gas Furnace Furnace

The chamber becomes corroded from the inside possibly due to a reaction from acidic condensation on the polypropylene coating.

Carrier furnace secondary heat exchanger problems.

The secondary heat exchanger is designed to extract the maximum remaining heat from the fuel source resulting in a normal condensation reaction. This problem happens due to corrosive nature of condensation water produced during combustion of natural gas and improper design in drainage system which keeps the acidic water in secondary heat exchangers exit point as shown in the. Exchanger part or furnace. The carrier high efficiency gas furnace trade in allowance program is designed to offer homeowners an alternative to replacing only the heat exchanger under the terms of their limited lifetime heat exchanger warranty on a first generation carrier condensing furnace if their furnace experiences a heat exchanger failure.

All secondary heat exchangers from replaced furnaces or whole furnaces replaced under this policy must be held at the distributor for potential factory inspection for thirty 30 days from distributor claim paid date. One the most common issues found in carrier high efficiency gas furnaces is corrosion or blockage is their secondary heat exchangers in approximately 5 to 10 years after the original installation date or in other words premature secondary heat exchanger failure. The truth is many homeowners have thought their carrier furnace wasn t working but all they needed to do was to turn on the system or turn up the heat. Sometimes the thermostat gets turned off or the setting changed by accident.

On january 3 2020 i purchased a carrier infinity 58mvc120f10120 which had the secondary heat exchanger plug up with corrosion therefore has caused numerous furnace issues over the past 3 years. This policy only covers the failure and required replacement of a secondary or condensing heat exchanger and the following related parts.

Heat Exchanger Replacement On A Bryant 340mav048100 Furnace Youtube

Heat Exchanger Replacement On A Bryant 340mav048100 Furnace Youtube

Carrier 58mtb Plugged Secondary Heat Exchanger Youtube

Carrier 58mtb Plugged Secondary Heat Exchanger Youtube

Replacing A Carrier Heat Exchanger A Day In The Life 6a Youtube

Replacing A Carrier Heat Exchanger A Day In The Life 6a Youtube

Bad Bryant Secondary Heat Exchanger 350mav048100 Youtube

Bad Bryant Secondary Heat Exchanger 350mav048100 Youtube